Download cable master
Author: i | 2025-04-24
Download Cable Master Electric Wire Find all the BASEC product and system approvals that are currently active for Cable Master Electric Wire Cable Co, Ltd. Download Cable Master Electric Wire Cable Co, Ltd. relevant certificates approved by BASEC.
Download Cable Master 2025.9.0.1.zip (Cable Master Software)
Each cable must be laid in parallel wiring continuously from the sensor to the PLC or control unit. Usually this has to be a shielded special cable. This means enormous costs for the often very expensive special cables, which also have to be laid over a long distance. In addition, this leads to a high installation effort for the cable ducts and brackets, as well as for connection of the entire cables by specialized plant electricians.The digital technology simplifies all this by connecting each device to a local IO-Link master with just one cable. From the master, only one cable is needed to connect to the PLC. As digital data transmission is resistant to interference, standard M12 cables are sufficient for this purpose.Our Tip: Our customers have reported both a 50 % reduction in labor costs and material costs for cable installation with new plant setups. Imagine cutting your cabling expenses in half – that‘s exactly what users have experienced. Calculate your own costs for cables and labor and see how much you could save with IO-Link.What advantages does IO-Link offer in the comissioning of plants?IO-Link devices are configured by connecting a computer to the IO-Link master. You just have to download sensor specific data, the IODD (IO Device Description) from a central database. Then you can enter the configuration of all the parameters, such as the measuring range for turbidity or the temperature display in either °C or °F, for the process. This programming is saved in the IO-Link master and can be copied directly to other sensors using copy-paste if multiple sensors need to be configured in the same way. This allows for faster set-up and fewer sources of error. You only have to use one interface to configure all devices and sensors, eliminating the need for product-specific Version but I am sure they both work the same way.Make sure you grab the correct bluetooth address from your phone, says it at the bottom of the phone in the app.Then download the drivers and sixaxis pair tool application on the PC, make sure they are installed! Grab your PS3 dualshock controller and connect it to your PC. It should go through installing the drivers/making sure you have them installed, once its complete your current controllers master will be shown at the top. You need to change it so that it reads the same as your mobile phones address.Once that is complete go back to your phone, open up the program and start the driver, now hold the ps button until you see it sync, if it isn't syncing then you have a problem with the address of either your phone or controller.Or...You can actually make a cheap OTG cable yourself with stuff you probably have laying around the house. All you need is an USB extender cable and a micro USB cable, along with some wire and a soldering kit. #5 When I used the app with my nexus s I had to use the computer tool, now with the galaxy all I had to do was plug it in with an otg cable, pair, and make sure you change the input method. Now I just start the app, press start on the app turn the controller on and it pairs instantly. #6 I have the AT&T version but I am sure they both work the same way.Make sure you grab the correct bluetooth address from your phone, says it at the bottom of the phone in the app.Then download the drivers and sixaxis pair tool application on the PC, make sure they are installed! Grab your PS3 dualshock controller and connect it to your PC. It should go through installing the drivers/making sure you have them installed, once its complete your current controllers master will be shown at the top. You need to change it so that it reads the same as your mobile phones address.Once that is complete go back to your phone, open up the program and start the driver, now hold the ps button until you see it sync, if it isn't syncing then you have a problem with the address of either your phone or controller.Or...You can actually make a cheap OTG cable yourself with stuff you probably have laying around the house. All you need is an USB extender cable and a micro USB cable, along with some wire and a soldering kit. I got everything down but for some reason the controller isn't saving the master change. As soon as ICable-Master Certificates - Cable Master Electric Wire Cable
Master or single drive. If you are installing your Seagate hard drive as the only drive in the system or if it will be the primary boot drive for the system, the jumper should be set as Cable Select. If you are connecting the drive to an older system that has a pre-UDMA Mode 3 ATA controller, or you are connecting this to a cable with a slave device that doesn’t have a cable select jumper setting, jumper the drive as Master instead by putting a jumper on the first vertical set of pins closest to the data cable.Drive as slaveIf you are installing the drive as an additional drive in your system, the drive should be set as Cable Select. If you are connecting the drive to an older system that has a pre-UDMA Mode 3 ATA controller, or you are connecting this to a cable with a master device that doesn’t have a cable select jumper setting, jumper the drive as Slave instead by removing the jumper from the drive.Cable SelectThis setting is the default setting for ATA drives. With the Cable Select jumper set, the BIOS determines whether a drive is a master or a slave by its position on the UltraATA cable. If the drive is jumpered as cable select and is connected to the black connector on the end of the cable, it is recognized as the master drive for that ATA controller. If the drive is jumpered as cable select and is connected to the grey connector on the middle of the cable, it is recognized as the slave drive for that ATA controller.Drive as master with a non-ATA-compatible slaveOn Seagate drives only, set a jumper on pins 5 and 6 and a jumper on pins 7 and 8. Use this jumper setting only if the drive does not work as a master or cable select.Limit drive capacity (or CLJ)Use this on computers manufactured before November 1998 when either you start up your computer and see the message, “Hard disc drive controller failure”, your computer does not recognize your newly installed hard drive, or. Download Cable Master Electric Wire Find all the BASEC product and system approvals that are currently active for Cable Master Electric Wire Cable Co, Ltd. Download Cable Master Electric Wire Cable Co, Ltd. relevant certificates approved by BASEC. Download Latest Version Cable Master 2025.9.0.1.zip (2.7 MB) Cable Master Official Sourforge Page Install Instruction - Install Cable Master Setup FirstCable-Master Frequently Asked Questions - Cable Master
Programming adapters, special hardware and software, or programming directly on the sensor display.Our Tip: Thanks to Flex-Hybrid technology, for existing analog systems you can also take advantage of these special benefits:Easy programming and configuration: all parameters can be set for all sensors easily on a laptop using only one software, even by someone outside of production or a plant engineer.Copy-paste for mutiple sensors: the settings only need to be made once and can then be saved in the IO-Link master, allowing for simple configuration of additional sensors with a few clicks using copy-paste.Automatic programming when replacing sensors: the programming saved in the IO-Link Master can be automatically transferred to the replacement sensor by plugging in the M12 cable.What do I need for the use of IO-Link and where can I find it?Thanks to the standardized communication protocol used across all sensors, actuators, and control components, setup and commissioning with IO-Link is simple and fast, even for those without expertise in the field. With just a few hardware and software components, you can get started with IO-Link:Master: This data hub, which is attached to the plant near the sensors, allows up to eight sensors or actuators to be plugged in via M12 cable. If more than eight devices are needed, several IO-Link masters can be connected to a central master with one cable each. Each Master model has its own software for configuration and operation of the connected devices.Cables: Thanks to the digital transmission‘s interference immunity, pre-made 3-pin M12 standard cables are sufficient.IODD: The „IO-Link Device Description“ is device-specific software necessary for operation via the IO-Link master. It can be downloaded from the IODD website or from any Anderson-Negele product page. Click here to open the IODD Download page.AOI: The „Add-On Instruction“ is required only by few PLC types. The AOIs Be set to match the shape of the work area 275° sensing angle Suitable for horizontal, vertical, and AGV applications Light immunity and dust resistant Dynamic and partial muting Multi-zone safeguarding via master-remote configuration Removable memory in Master models for fast scanner replacement Master and Remote connection reduces wiring Field replaceable window Safety Scanner Software Simple setup for rapid deployment The SX5 can be set up in just a few simple steps using Banner’s free configuration software. This robust software features menu-driven tools that guide users through setup and make it easy to design custom safety and warning zones to accommodate existing infrastructure and meet the specific needs of any application. The software interface makes it easy to create custom safety and warning zones to safeguard large, complex, and irregularly shaped areas SX Laser Scanner Datasheet Banner Laser Scanner Model #s Scanner Kits ModelDescriptionCable LengthIncluded SCAN021Kit SX Laser Scanner15 Meter CableIncludes: RBL106 scanner, RBL101 15m cable, RBL104 Bracket, RBL105 Programming Cable SCAN022Kit SX Laser Scanner30 Meter CableIncludes: RBL106 scanner, RBL102 30m cable, RBL104 Bracket, RBL105 Programming Cable SCAN030Kit Simple Function Laser Scanner SZ 1 Zone30 Meter CableIncludes: RKL01S scanner, RKLP30PS 30m cable, RKL86937 Horizontal Bracket, RKL8693 Vertical Bracket SCAN031Kit Multi-Function Laser Scanner SZ-V Long Distance W/O Camera30 Meter CableIncludes RKLV04 scanner, RKLVP30 30m cable, RKLVB01 Horizontal Bracket, RKLVB02 Vertical Bracket SCAN 032Kit Add One Multi-Function Laser Scanner SZ-V Long Distance W/O Camera20 Meter Daisy CableIncludes: RKLV04 scanner, RKLVS20 20m daisy cable, RKLVB01 Horizontal Bracket, RKLVB02 Vertical Bracket Scanners ModelDescriptionDegreeRange RBL106ScannerCable Master 2025.2 Download (Free) - Cable Master.exe
InformationNew Controller and Lock Power Supplies. Same Specifications / New Mounting Bracket. See instructions below on how to install.RWS-150/15/28 SpecsRWS-150/15/28 Installation Instructions The DSX-LAN-D is the latest in LAN communications interface and can replace all older DSX-LAN modules. The DSX-IP-HUB is a communication distribution module allowing the Master to Communicate with the Sub Controllers via IP without the use of PC Master Software. These units are programmed with a web browser. They have a default IP address of 192.168.1.25. The Links below are to the installation and configuration documents. These new LAN-D and HUB modules require the TX and RX Ports to be the same in both the software and module.DSX-LAN-D configuration DSX-IP-HUB configuration DSX LAN-D and IP-Hub Upgrade and Factory Default Instructions DSX-USB Communication Module Instructions includes loading the driverDSX-LAN. The Link below will allow you to download the following files for programming the DSX-LAN Module: IPSetup.exe, LanModuleSerialSetup.exe, LanMod2.pdf. configuration - Here are the instructions for the DSX-LAN-MBelow is a link to the DSX Cable Specifications. Using the specified cables will prevent many problems. These are the cable specifications for all generations of DSX Hardware. Please see the link below for specific cables required for communications, readers & keypads, locks, inputs, transformers, elevators and LAN. These specified or equivalent cables are the only ones DSX will support. These are the cables tested with the system and approved by UL. "CAT_5"CAT 5/6 cable should only be used for network connections to the DSX-LAN module. IT SHOULD NEVER be used for anything else. It will not function properly for panel communications. DSX Cable SpecificationsNo Communication to the Master Controller can be due to several errors in configuration among other things such as firewalls. In WinDSX it is important to check these items:a. There must be a Device 0 defined under Devices. In Location/Numeric Options Tab/ Connect Type must be Direct for all LAN, USB, and Serial Communications.b. There must be a unique Comm Port defined. For LAN communications the Port Type must be LAN TCP/IP, The IP Address must match that of the LAN module. c. The Transmit Port (TXIP Port) must match the Receive Port of the LAN Module. The Receive Port (RX IP Port) is typically 0 but if defined must match the Transmit Port of the LAN module (LAN-D’s require this). Please see configuration examples in LAN module instructions for more information on how to apply these settingsCable Master 2025.5 Download (Free) - Cable Master.exe
Eliminate excess energy use and trim utility bills with this energy saving advanced power strip. It works by intelligently cutting off power to connected devices when they're not in use, eliminating phantom and standby power losses without ever unplugging the equipment.This power strip:Includes load-sensing technology that detects the current being drawn through the master outlet, which is plugged into a primary device like a TV or computer. Peripheral devices like game consoles, DVD players or monitors are plugged into the switched outlets, which only become energized when a high current is detected in the master outlet, indicating the TV or computer is powered on.Features always-on outlets to provide power at all times, so they can be used for devices that need power constantly, like modems and cable boxes.Includes a 3-ft. heavy-duty cord.Features an angled space-saver plug.Includes child-protective outlet covers.Outlets and hardware:1 master outlet (transformer spaced)Includes 2 always-on outletsIncludes 4 switched outletsProduct Warranty: 10 YearsDownload a spec sheetWant to learn more about setting up this power strip?Download a user guideWatch the setup video for the Simply Conserve® power strip.. Download Cable Master Electric Wire Find all the BASEC product and system approvals that are currently active for Cable Master Electric Wire Cable Co, Ltd. Download Cable Master Electric Wire Cable Co, Ltd. relevant certificates approved by BASEC. Download Latest Version Cable Master 2025.9.0.1.zip (2.7 MB) Cable Master Official Sourforge Page Install Instruction - Install Cable Master Setup FirstCable Master 2025.6 Download (Free) - Cable Master.exe
INFORMATION OverviewBD-2EOC-2GE is the integrate EOC Master with two EOC master module and one Media Converter module.The BD-2EOC-2GE EOC Master can provide high speed data service based on coaxial cable network. BD-2EOC-2GE built in a media convert, 10/100/1000Mbps media converter. The module supports IEEE 802.3, 802.3ab, 802.3u, 802.3z standards. It provide one SC/PC optical connector for 1000Base-Lx and four 10/100/1000M auto-negotiable Ethernet RJ45 interface. It can work with our MC head-end products and compliant with the third-party equipment. The EOC Master Module is based the Qualcomm AR7410 chipset solution,with high anti jamming capability OFDM technology. The 7.5-65MHz low frequency band is used for EOC signals. Built in high isolation filter as CATV RF and EOC signal mixer, the EOC signal and CATV signal in 87~862MHz can run on one cable without interference. The EOC Master can provide high speed data service. The PHY Layer speed is 600Mbps, the MAC Layer throughput is up to 320Mpbs.The MC module connects with the EOC module, Ethernet data signals will be modulated into RF signals to transmit in the coaxial cable. BD-2EOC-2GE integrating EOC and MC can reduce the number of active node, decreasing failure rate and saving a space. It is the best choice of LAN+EOC solution for the operator. Function Features● High integration with two EOC Master modules and one MC module ● Aluminum alloy die casting shaping, good heat dissipation ● Outdoor waterproof designed, 60V/220V power supply optional ● 7.5-65Mhz frequency for EOC signals., no influence on CATV Service ● Support broadcast storm limitation ● Support data packet statistics ● Support auto-update and auto-configuration ● Support On-line upgradingSupport optical power measuring ● Flexible bandwidth allocation function ● Provide QOS for different service requirement ● Provide fault alarm function , easy for troubleshooting ● MC module is one standard media converter, provide different optical connector for different applicatio requirement ● Network management optional ● Compliant with the third-party equipment ● Support EMS based SNMPSpecificationItemParametersSpecificationSpecification of EOC ModuleInterface and LED IndicatorRF Port1*EOC low-frequency signal output port, support F- Female or SMB connectorEthernet Port2*2 10/100/1000M auto-negotiation, RJ45LED Indicator2*1 for Power Supply Status2*1 CABLE LinkComments
Each cable must be laid in parallel wiring continuously from the sensor to the PLC or control unit. Usually this has to be a shielded special cable. This means enormous costs for the often very expensive special cables, which also have to be laid over a long distance. In addition, this leads to a high installation effort for the cable ducts and brackets, as well as for connection of the entire cables by specialized plant electricians.The digital technology simplifies all this by connecting each device to a local IO-Link master with just one cable. From the master, only one cable is needed to connect to the PLC. As digital data transmission is resistant to interference, standard M12 cables are sufficient for this purpose.Our Tip: Our customers have reported both a 50 % reduction in labor costs and material costs for cable installation with new plant setups. Imagine cutting your cabling expenses in half – that‘s exactly what users have experienced. Calculate your own costs for cables and labor and see how much you could save with IO-Link.What advantages does IO-Link offer in the comissioning of plants?IO-Link devices are configured by connecting a computer to the IO-Link master. You just have to download sensor specific data, the IODD (IO Device Description) from a central database. Then you can enter the configuration of all the parameters, such as the measuring range for turbidity or the temperature display in either °C or °F, for the process. This programming is saved in the IO-Link master and can be copied directly to other sensors using copy-paste if multiple sensors need to be configured in the same way. This allows for faster set-up and fewer sources of error. You only have to use one interface to configure all devices and sensors, eliminating the need for product-specific
2025-04-16Version but I am sure they both work the same way.Make sure you grab the correct bluetooth address from your phone, says it at the bottom of the phone in the app.Then download the drivers and sixaxis pair tool application on the PC, make sure they are installed! Grab your PS3 dualshock controller and connect it to your PC. It should go through installing the drivers/making sure you have them installed, once its complete your current controllers master will be shown at the top. You need to change it so that it reads the same as your mobile phones address.Once that is complete go back to your phone, open up the program and start the driver, now hold the ps button until you see it sync, if it isn't syncing then you have a problem with the address of either your phone or controller.Or...You can actually make a cheap OTG cable yourself with stuff you probably have laying around the house. All you need is an USB extender cable and a micro USB cable, along with some wire and a soldering kit. #5 When I used the app with my nexus s I had to use the computer tool, now with the galaxy all I had to do was plug it in with an otg cable, pair, and make sure you change the input method. Now I just start the app, press start on the app turn the controller on and it pairs instantly. #6 I have the AT&T version but I am sure they both work the same way.Make sure you grab the correct bluetooth address from your phone, says it at the bottom of the phone in the app.Then download the drivers and sixaxis pair tool application on the PC, make sure they are installed! Grab your PS3 dualshock controller and connect it to your PC. It should go through installing the drivers/making sure you have them installed, once its complete your current controllers master will be shown at the top. You need to change it so that it reads the same as your mobile phones address.Once that is complete go back to your phone, open up the program and start the driver, now hold the ps button until you see it sync, if it isn't syncing then you have a problem with the address of either your phone or controller.Or...You can actually make a cheap OTG cable yourself with stuff you probably have laying around the house. All you need is an USB extender cable and a micro USB cable, along with some wire and a soldering kit. I got everything down but for some reason the controller isn't saving the master change. As soon as I
2025-03-29Master or single drive. If you are installing your Seagate hard drive as the only drive in the system or if it will be the primary boot drive for the system, the jumper should be set as Cable Select. If you are connecting the drive to an older system that has a pre-UDMA Mode 3 ATA controller, or you are connecting this to a cable with a slave device that doesn’t have a cable select jumper setting, jumper the drive as Master instead by putting a jumper on the first vertical set of pins closest to the data cable.Drive as slaveIf you are installing the drive as an additional drive in your system, the drive should be set as Cable Select. If you are connecting the drive to an older system that has a pre-UDMA Mode 3 ATA controller, or you are connecting this to a cable with a master device that doesn’t have a cable select jumper setting, jumper the drive as Slave instead by removing the jumper from the drive.Cable SelectThis setting is the default setting for ATA drives. With the Cable Select jumper set, the BIOS determines whether a drive is a master or a slave by its position on the UltraATA cable. If the drive is jumpered as cable select and is connected to the black connector on the end of the cable, it is recognized as the master drive for that ATA controller. If the drive is jumpered as cable select and is connected to the grey connector on the middle of the cable, it is recognized as the slave drive for that ATA controller.Drive as master with a non-ATA-compatible slaveOn Seagate drives only, set a jumper on pins 5 and 6 and a jumper on pins 7 and 8. Use this jumper setting only if the drive does not work as a master or cable select.Limit drive capacity (or CLJ)Use this on computers manufactured before November 1998 when either you start up your computer and see the message, “Hard disc drive controller failure”, your computer does not recognize your newly installed hard drive, or
2025-04-08Programming adapters, special hardware and software, or programming directly on the sensor display.Our Tip: Thanks to Flex-Hybrid technology, for existing analog systems you can also take advantage of these special benefits:Easy programming and configuration: all parameters can be set for all sensors easily on a laptop using only one software, even by someone outside of production or a plant engineer.Copy-paste for mutiple sensors: the settings only need to be made once and can then be saved in the IO-Link master, allowing for simple configuration of additional sensors with a few clicks using copy-paste.Automatic programming when replacing sensors: the programming saved in the IO-Link Master can be automatically transferred to the replacement sensor by plugging in the M12 cable.What do I need for the use of IO-Link and where can I find it?Thanks to the standardized communication protocol used across all sensors, actuators, and control components, setup and commissioning with IO-Link is simple and fast, even for those without expertise in the field. With just a few hardware and software components, you can get started with IO-Link:Master: This data hub, which is attached to the plant near the sensors, allows up to eight sensors or actuators to be plugged in via M12 cable. If more than eight devices are needed, several IO-Link masters can be connected to a central master with one cable each. Each Master model has its own software for configuration and operation of the connected devices.Cables: Thanks to the digital transmission‘s interference immunity, pre-made 3-pin M12 standard cables are sufficient.IODD: The „IO-Link Device Description“ is device-specific software necessary for operation via the IO-Link master. It can be downloaded from the IODD website or from any Anderson-Negele product page. Click here to open the IODD Download page.AOI: The „Add-On Instruction“ is required only by few PLC types. The AOIs
2025-04-19Be set to match the shape of the work area 275° sensing angle Suitable for horizontal, vertical, and AGV applications Light immunity and dust resistant Dynamic and partial muting Multi-zone safeguarding via master-remote configuration Removable memory in Master models for fast scanner replacement Master and Remote connection reduces wiring Field replaceable window Safety Scanner Software Simple setup for rapid deployment The SX5 can be set up in just a few simple steps using Banner’s free configuration software. This robust software features menu-driven tools that guide users through setup and make it easy to design custom safety and warning zones to accommodate existing infrastructure and meet the specific needs of any application. The software interface makes it easy to create custom safety and warning zones to safeguard large, complex, and irregularly shaped areas SX Laser Scanner Datasheet Banner Laser Scanner Model #s Scanner Kits ModelDescriptionCable LengthIncluded SCAN021Kit SX Laser Scanner15 Meter CableIncludes: RBL106 scanner, RBL101 15m cable, RBL104 Bracket, RBL105 Programming Cable SCAN022Kit SX Laser Scanner30 Meter CableIncludes: RBL106 scanner, RBL102 30m cable, RBL104 Bracket, RBL105 Programming Cable SCAN030Kit Simple Function Laser Scanner SZ 1 Zone30 Meter CableIncludes: RKL01S scanner, RKLP30PS 30m cable, RKL86937 Horizontal Bracket, RKL8693 Vertical Bracket SCAN031Kit Multi-Function Laser Scanner SZ-V Long Distance W/O Camera30 Meter CableIncludes RKLV04 scanner, RKLVP30 30m cable, RKLVB01 Horizontal Bracket, RKLVB02 Vertical Bracket SCAN 032Kit Add One Multi-Function Laser Scanner SZ-V Long Distance W/O Camera20 Meter Daisy CableIncludes: RKLV04 scanner, RKLVS20 20m daisy cable, RKLVB01 Horizontal Bracket, RKLVB02 Vertical Bracket Scanners ModelDescriptionDegreeRange RBL106Scanner
2025-04-05